ISO 15189:2022 and NABL 112 compliance matrix

Which clause is covered by which QCnomics module, stated honestly: supported, partly, planned or not covered.

This page maps the clauses of ISO 15189:2022 (and the NABL 112 specific criteria that build on it) to the QCnomics module that provides the evidence for each. It is written for quality managers and assessors who want to know what the software actually covers before they rely on it. Nothing here claims that NABL, or any accreditation body, endorses the software: accreditation is granted to laboratories, and QCnomics is the tool that keeps their evidence in order.

How to read the status column. Supported: the clause has a dedicated module and the records it produces are what an assessor asks for. Partly: the module covers the records but not every requirement of the clause (the gap is stated). Planned: on the roadmap. Not covered: the laboratory needs another system or a paper record.

ClauseRequirementWhat QCnomics doesModuleStatus
4.1–4.3Impartiality, confidentiality, patient-centredPer-laboratory data isolation, role-based access, audit trail of every record; patient feedback module.Audit Trail · Users & Access · Patient FeedbackSupported
5.1–5.3Legal entity, laboratory director, laboratory activitiesLegal licence register with expiry reminders (Clinical Establishments Act, BMW authorisation, PCPNDT, NABL certificate, agreements); scope of activities per section.Legal Compliance · Lab SetupSupported
5.5 / 8.1Management system requirementsQuality manual, policies and SOPs under document control with versions, approvals and read-acknowledgement.Document Control · Controlled ManualsSupported
6.2Personnel: competence, authorisation, training, recordsPersonnel records, job descriptions, qualification documents, competence assessment, training (LMS) with certificates, vaccination / health records.Personnel (HRM) · Training (LMS)Supported
6.3Facilities and environmental conditionsRoom and refrigerator temperature / humidity logs with limits, missed-reading alerts and e-mail reminders.Environmental MonitoringSupported
6.4Equipment: acquisition, acceptance, use, maintenance, repair, recordsEquipment master with history, daily/weekly checklists linked to analyzers, calibration and verification records with due dates, breakdown and maintenance events, condemnation.Equipment & Calibration · Equipment ChecklistSupported
6.4.5 / 7.3.7.1Equipment calibration and metrological traceabilityInstrument calibration records; reagent/analyte calibration log with calibrator lot, factor, QC-after check, correlation with IQC and EQAS, 6-monthly verification reminders (CLIA 493.1255).Calibration & CorrelationSupported
6.5Equipment calibration and traceability of measurement resultsCalibrator lot and traceability statement per calibration; measurement uncertainty from IQC.Calibration & Correlation · Sigma QCPartly
6.6Reagents and consumables: reception, storage, acceptance testing, inventoryQC material and reagent lot records with open-vial stability and expiry; lot-to-lot verification (NABL 112A) per CLSI EP26; reagent lot change correlated with QC and calibration.QC / Reagent Lots · Calibration & CorrelationSupported
6.7Service agreementsAgreements and MoUs (referral lab, AMC, courier, CBWTF) with signed-copy upload and renewal reminders.Legal ComplianceSupported
6.8Externally provided products and servicesReferral laboratory agreements; supplier records.Legal CompliancePartly
7.2Pre-examination processesSample rejection log with reasons and quality indicators; collection centre management; critical-value reporting log.Sample Rejection · Collection Centres · Critical ValuesPartly
7.3.1–7.3.3Examination processes: verification and validation of methodsMethod validation / verification studies (precision, bias, linearity, reference interval), carry-over study, inter-instrument comparison, LIS verification.Method Validation · Carry-over Study · Inter-instrument · LIS VerificationSupported
7.3.4Measurement uncertaintyMU from IQC imprecision and EQAS bias per analyte, U (k=2) compared with TEa; MU calculator.Sigma QC · Calibration & CorrelationSupported
7.3.7.2Internal quality controlDaily QC entry or automatic capture from analyzers (ASTM / HL7 / serial / file), Levey-Jennings, Westgard multirules, sigma-based rule selection, run review, repeat tracking, QC due alerts, monthly review of mean/SD.QC Entry · Auto QC (HL7) · Levey-Jennings · Violations & CAPA · Sigma QCSupported
7.3.7.3External quality assessment (EQA / proficiency testing)EQAS programme calendar, result entry, bias / SDI, unacceptable-result CAPA opened automatically, correlation with calibration and IQC.EQA / Proficiency TestingSupported
7.3.7.4Comparability of examination resultsInter-instrument comparison studies; peer comparison of QC across laboratories.Inter-instrument · Peer CompareSupported
7.4Post-examination: reporting, release, retention of samplesRetained sample register; critical-value log; auto-verification rules documentation.Retained Sample · Critical Values · Auto-verificationPartly
7.5Nonconforming workDaily nonconformance log, incident reports, QC rejections with run review and hold on patient results.Daily NC · Incident Report · Violations & CAPASupported
7.6Control of data and information managementCloud hosting with daily backups, version history of every change, audit trail, LIS verification records.Audit Trail · LIS VerificationSupported
7.7ComplaintsPatient feedback and complaint log with resolution tracking.Patient FeedbackSupported
7.8Continuity and emergency preparednessNot covered by a dedicated module; risk register can hold the plan.Risk ManagementNot covered
8.2–8.4Management system documentation, control of documents and recordsDocument control with approval workflow, obsolete-document control, record retention periods.Document ControlSupported
8.5Risk and opportunities for improvementRisk register with likelihood/impact scoring and treatment; quality indicators with targets.Risk Management · Quality IndicatorsSupported
8.6ImprovementQuality indicator dashboard, patient feedback, improvement actions.Quality IndicatorsSupported
8.7Nonconformities and corrective actionsCAPA register with the five mandatory steps, automatic CAPA on QC rejection and EQAS failure, effectiveness check after 10 in-control runs, root-cause tools.Violations & CAPA · CAPA RegisterSupported
8.8Evaluations: internal audit, quality indicators, EQA reviewInternal audit with clause-wise checklist, findings and follow-up; indicator review; EQA review.Internal Audit · Quality IndicatorsSupported
8.9Management reviewManagement review meeting with the ISO 15189 input list pre-filled from the modules, decisions and actions tracked.Management ReviewSupported
NABL 112 Cl. iiLaboratory size classificationLab size recorded at sign-up; plan by number of analytes.Lab SetupSupported
NABL 112 Cl. 6(d)Reagent / calibrator recordsCalibrator lot and expiry on every calibration; reagent lot records.Calibration & Correlation · QC / Reagent LotsSupported
NABL 112ALot-to-lot verification, QC frequencyLot-to-lot verification workflow and EP26 judgment limits; QC frequency plans per section.QC / Reagent Lots · Lab SetupSupported
NABL 153 / 155Application and assessment formsReadiness assessment with clause-wise score; evidence pack export per clause.NABL CompliancePartly
POCT (ISO 22870 / NABL)Point-of-care testingPOCT device register, operator competence and QC.POCTPartly
Counts: 26 supported, 6 partly, 0 planned, 1 not covered, of 33 requirements. Last reviewed 2026-10-28.

Evidence an assessor can ask for

Each module exports its records as PDF with the laboratory name, a generated timestamp, page numbers and a reviewed-by line: Levey-Jennings charts with Westgard violations, monthly QC review, calibration and correlation reports with sigma metrics, EQAS summaries, CAPA records with effectiveness evidence, equipment history, training and competence records, internal audit reports and management review minutes. The audit trail records who changed what and when for every record.

What QCnomics does not do

It is not a laboratory information system: it does not register patients, print patient reports or bill. It reads the QC results from the analyzer's LIS traffic or receives them directly, and leaves patient results alone. It does not provide proficiency-testing samples (it manages the results of the EQAS scheme the laboratory subscribes to). Continuity planning (7.8) and purchasing (6.8) have no dedicated module.

Frequently asked questions

Is QCnomics NABL approved or certified?

No software is approved or certified by NABL. NABL accredits laboratories against ISO 15189:2022 and NABL 112. QCnomics is built so that the records it keeps match what those criteria ask for, as set out in the matrix on this page.

Does QCnomics cover ISO 15189:2022 or only the 2012 edition?

The matrix, the internal audit checklist and the management review inputs follow the 2022 edition (ISO 15189:2022), including clause 7.3.7 for IQC and EQA and clause 8 for the management system.

Can a laboratory use QCnomics only for internal quality control?

Yes. Many laboratories start with QC Entry, Auto QC and Levey-Jennings and add the management-system modules later. Pricing is by the number of analytes under QC, not by module.